The conditioner is rather difficult engineering device demanding observance of the corresponding rules at its operation. As well as any technical system, the conditioner can fail at incorrect use or for other reasons. If the device does not work properly, do not despair. You can try to eliminate some types of malfunctions of the conditioner independently, without participation of the expert.

1. The most widespread fault of the conditioner – when is completely hammered the filter of its internal part. Figuratively speaking the device ceases "to breathe", there is reduction of giving of cold or heat, engine seizure, substandard operation of the fan. To prevent emergence of these malfunctions, you regularly make preventive cleaning of filters, following the instruction attached to the device.

2. Quite often other, "imaginary" fault connected with incorrect use of the remote control meets. Pay attention to value of temperature set in the device and that which actually is available indoors. In order that the mode of cooling worked correctly, set temperature which will be lower than room. If you want the conditioner to work for heat radiation, establish on the thermostat temperature above room.

3. If there is termination of performance of all functions on the display or the panel of the conditioner, then probably the fault connected with payment of management takes place. Sometimes this situation can be corrected, having used the Reset function or blackout of the device from network for several minutes. If the specified measures have not led to conditioner unblocking, intervention of the qualified specialist in repair will be required.

4. In the presence of leak of water from the conditioner it is possible to draw conclusion on contamination of system of drainage. To eliminate blockage, take the drainage call which goes outside from the conditioner, and properly blow it. As soon as from tube water has gone, it means that the blockage is eliminated.

5. One of sure signs of shortage of freon in the cooling system of the conditioner is the hoarfrost covering copper tube of large diameter on external part of the device. The second sign of such fault – the conditioner develops not enough cold at normally cleaned filters and regularly running engine. You will hardly be able to eliminate such fault therefore address to the service center for elimination of malfunction by the expert.